GS-145 Hydraulic Power Station

Send Request
Hydraulic stations
GS-145 Hydraulic Power Station
Question
Name
Phone
E-mail
Back call
Hydraulic stations
GS-145 Hydraulic Power Station
Name
Phone
Back call
Write to us
Add to cart
Purpose
Characteristics
Composition station

The hydraulic power station is designed to convert electric energy into hydraulic energy of the power fluid flow as well as to transport the power fluid to operating hydraulic units and back. The station is blast-resistant to allow for operation in explosion and fire hazardous conditions.

The main purpose of the station is joint operation with hydraulic tongs, but it may also be used with other products.

Climatic category is UHL1 according to GOST 15150-69, ambient temperature in the course of operation is from -45°С to 50°С.

Name of parameter, unit of measurement

Nominal value

Oil tank volume, l

400

Volumetric supply to the hydraulic system at a pressure of up to 7 MPa, l/min

150

Volumetric supply to the hydraulic system at a pressure exceeding 7 MPa, l/min

58

Maximum injection pressure, MPa

20

Dimensions (length x height x width), not more than, mm

1700x1300x1300

Hydraulic pump

feed per turn (section 1/section 2), cm3

Two-section

80/45

Station (hydraulic pump) drive:

- power, kW

- shaft speed, rpm

Electric motor

30

1500

Rotational direction of the hydraulic pump motor shaft

(when looking from the shaft side)

Right (clockwise)

Heating of power fluid

A set of 3 heating elements of 2kW each, heated medium is oil

Cooling of power fluid:

Air-to-oil heat exchanger with an electric blower and a thermostatic valve

Temperature control

Heat converter

Control of power fluid level in the tank

Level gage

Weight of the station filled with oil, not more, kg

1300

Cleanliness of power fluid as per GOST 17216

At least grade 12

Explosion safety as per GOST R 51330.0

1ExdIIBT4

Power supply

50 Hz, 380V

Maximum power consumption, kW

37

The station consists of the following main components:

  • induction motor;

  • two-section hydraulic pump;

  • valve block with manifold system;

  • oil tank;

  • set of heating elements for oil heating;

  • drain filter;

  • pressure filter (2 pcs);

  • thermal converter;

  • capacitive switch (level sensor);

  • breather filter with filler neck;

  • air-to-oil heat exchanger;

  • quick connections;

  • frame;

  • electrical control cabinet.

Also, the station may be supplied in the container upon the individual request of the Buyer.